Home » Wiring Cables » Submersible 3 - Core Flat Cables

Submersible 3 - Core Flat CablesKundan Cab Pvt Ltd




Submersible 3 - Core Flat Cables

Range of Submersible 3 - Core Flat Cables

1.5 Sq mm to 50 Sq mm Submersible 3 - Core Flat Cables
Submersible 3 - Core Flat Cables Pump cables is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Kundan cab Submersible 3 - Core Flat Cables is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability.

For trouble free working, this connecting cables are used for submersible pump motors. Kundan Cab 3 Core Flat Cables are manufactured keeping in mind the severe and difficult conditions in which they are required to perform. The individual conductors are made from bright electrolytic grade copper. These wires are drawn, annealed and bunched properly to ensure flexibility and uniform resistance. Each of the 3 copper conductors is insulated with special PVC compound. The cores are laid up in flat parallel position. The outer sheath of the cable is made from a special grade of abression resistance PVC compound impervious to water, grease, oil etc.

Note :
The strand diameter is nominal however, construction of conductor is design to satisfy the requirements of conductor resistance as per IS:8130:1984. *As per conductor class 2 of IS:8130:1984 **As per conductor class 5 of IS:8130:1984

3 Core Flat Cables as per IS:694:1990 with ISI mark
ConductorInsulationSheath
Overall Dimensions
Conductor Resistance @20°C (max.)ohms/km.Current Carrying Capacity @ 40°C (Amp.)
Area (Nom.) Sq. mm.No./size of Wires mmThickness (Nom) mm.Core Dia. (Nom) mm.Thickness (Nom) mm.Width 'W' mmThickness 'T'mm
1.522/0.30.83.251.1512.55.812.1014
2.536/0.30.93.901.1514.46.37.4118
456/0.31.04.651.1517.27.44.9526


3 Core Flat Cables generally conforming to IS:694:1990
ConductorInsulationSheath
Overall Dimensions
Conductor Resistance @ 20°C (max.) ohms/km.Current Carrying Capacity @ 40°C (Amp.)
Area (Nom.) Sq. mm.No./size of Wires mmThickness (Nom) mm.Core Dia. (Nom) mm.Thickness (Nom) mm.Width 'W' mmThickness 'T'mm
6.084/0.31.05.201.1518.77.93.3031
10.0140/0.31.06.601.4023.79.91.9142
16.0226/0.31.08.201.4028.011.41.2157


Selection Guide for 3 Core Flat Cables
1) HP Vs Current: The full load current for submersible pump motors, 3 phase, 50 cycles, 415~425 V.
Hp5.07.510.012.515.017.520.025.030.035.040.045.050.055.060.065.070.075.080.0
Amp7.511.014.918.922.525.228.435.642.350.458.162.167.573.881.087.393.6100.80108.0


2) Derating Factors: Multiply the current carrying capacity of the cable by factors given below for various ambient temperatures.
Ambient Temperature C3035404550
Operating Factor1.091.041.000.950.77


Note: